We provide the reliable carbon dioxide OEM solutions, with multiple protocols, so that products can be quickly upgraded and assembled. There is an internal atmospheric pressure sensor, which can automatically adjust the atmospheric pressure and suitable for various altitude ranges and harsh environments The monitor only needs one interface, which can be connected to the module for use. It can be used in conjunction with a multi-parameter monitor. Consistent with other gas measurement modalities such asmass spectrometry, these early devices were sidestream (i.e.,diverting) sampling systems. In the 1950’sthese bulky and fragile instruments were adapted for medicaluse. With the self-developed adapters, they can continuously work for a long time in high temperature environment. Infrared measurement of carbon dioxide monitoring(capnography) dates back to the 1940’s 1,2. It is equipped with high-quality Multi-Channel Narrowband Filters, IR Light Source, Well-designed Hardware Circuit and Software Algorithms to achieve gas concentration measurement with high signal-to-noise ratio Statistical methods are used to find the best setting for sampling respiratory signals and improving precision. This capnometer inhibits signal drift by using electric modulation and thus ensures the accuracy of long-term CO 2 monitoring. The relationship of CO 2 concentration to time is graphically represented by the CO 2 waveform, or capnogram ( figure 1 ). A type of mainstream capnometer based on the principle of non-dispersive infrared was designed. Mainstream Capnography Sensor Capno-M Application Scenarios The term capnography refers to the noninvasive measurement of the partial pressure of carbon dioxide (CO 2) in exhaled breath expressed as the CO 2 concentration over time. The correlation coefficient and degree of bias between EtCO 2 and PaCO 2 were assessed for various clinical situations. IEC 6,EN55011 - CISPIR 11 Class B IEC6 Electrostatic Discharge lmmunity,IEC 6 Radiated lmmunity, Designed to comply with 93/42/EEC (MDD CE Marking), FDAStandards, Minimum Performance and Safety Requirementsfor Capnometers ISO8 In short, the fundamental difference between mainstream and sidestream is whether to divert gas from the airway for analysis. by mainstream capnography and had indwelling arterial catheter. A Cap-ONE mask is a multi-functional face mask which can allow oxygen supply and simultaneous end-tidal CO 2 (ETCO 2) measurement in infant and pediatric as well as an adult patient. Regulatory Designed to meet the following standards Background: Capnography is useful for identifying postoperative apnea in non-intubated children. IEC TR 6 Class 7M3,EN6 Shock,EN6 Random vibration Shortly drifting less than 1mmHg,after 4 hours' power on.Longly drifting does not influence nominal accuracy aftercontinuous 140 hours' power on. To reach designed deviation 97% within 8s, toreach designed deviation within 20s Advantages: Sensor placed in breathin circuit. One end plugs into the 92517 module and the other end, with the integrated sensor. Mainstream The mainstream analysier chamber placed between the endotracheal tube and the ventilator circuit. RS-232/ Standard E-8-1,38.4 kBaud,10ms data interval(KM) or customized communication 2 measurement range: 0-19.7%,150mmHg,or 0-20kPaĤ1 - 70 mmHg 土 5% of reading 71 - 100 mmHg 土 8% of reading 101 - 150 mmHg 10% of reading Respiration rate: 2-150 bpm Mainstream etCO2 sensor for use only with the Capnography Module 92517. Mainstream capnography is most commonly used for mechanically ventilated patients and intubated patients who require intensive monitoring. Non-dispersive infrared gas analysis, Multi-channel infrared detector, Infrared resource, no moving portsĥ to 50°℃,10 to 90% RH, non-condensingCircumstance pressure:55-115kPĥ V+5%(max ripple 200 mVp-p)Power consumption:<150mA The Capnograph connects with patient’ respiratory tract by the airway adapter and breathing tube.Specifications of Mainstream EtCO2 Capnography Module Capno-M Technique The application population is adult, pediatric and neonate patients. Excellent customer service + same-day shipping. It can detect pulmonary ventilation function and reflect the circulation and pulmonary blood flow condition, as well as indirectly reflect the alveolar ventilation, which is applicable for use in pre-hospital emergency transfer, emergency department, ICU, operating room, neonatology, respiratory department and other occasions. Masimo Compatible EtCO2 Sensor Mainstream Capnography at a low price. Capnograph adopts mainstream method to measure the end-tidal carbon dioxide, airway respiration rate and other parameters.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |